RESEARCH OF THE INFLUENCE OF HEATING DEVICES AND RECIRCULATORS ON THE AEROIONIC COMPOSITION OF AIR IN THE PRODUCTION ZONE
DOI:
https://doi.org/10.26906/SUNZ.2024.1.181Keywords:
aerions, microclimate, thermal fan, recirculator, infrared heaterAbstract
Pyrpose. Research of the effect of heating devices and a recirculator on the concentration and aerodynamic distribution of ions of both polarities in the production room. Methodology. The study of the quantitative composition of aeroions using an empirical method during a field experiment, statistical analysis and approximation of experimentally obtained data. Findings. Based on empirical data and obtained dependencies, it was established that during the use of a fan heater, the concentration of negative aerions increases by 1.7 times, and positive ions by 2.1 times. At the same time, the use of a recirculator increases the concentration of negative air ions by 2.2 times, and positive ones by 2.8 times. Originality. For the first time, the influence of heating devices of various types and a recirculator on the quantitative composition of aerions in the production zone was evaluated. Practical value. Establishing patterns of air ionization (deionization) during the use of heating devices and a recirculator in the context of creating a safe working environment for employees.Downloads
References
Shu-Ye Jiang, Ali Ma and Srinivasan Ramachandran Negative Air Ions and Their Effects on Human Health and Air Quality Improvement. International Journal of Molecular Sciences. 2018, 19, 2966.
Bailey, W.H.; Williams, A.L.; Leonhard, M.J. Exposure of laboratory animals to small air ions A systematic review of biological and behavioral studies. BioMed. Eng. online 2018, 17, 72.
Lazzerini, F.T.; Orlando, M.T.; De Prá, W. Progress of negative air ions in health tourism environments applications. Bol. Soc. Esp. Hidrol. Méd. 2018, 33, 27–46.
Zhou, P.; Yang, Y.; Huang, G.; Lai, A.C.K. Numerical and experimental study on airborne disinfection by negative ions in air duct flow. Build. Environ. 2018, 127, 204–210.
Ченчева, О. О., Бурдейна, Н. Б., Лашко, Є. Є., Шевченко, В. Г., Петренко І. С. (2022). Вплив пилоутворення при механічному обробленні карбон-карбонових композитів на ризик виникнення професійних захворювань. Проблеми охорони праці в Україні, 38(3–4), 25–33.
Ченчевой В. В., Сукач С. В., Ченчева О. О., Федорова Н. С., Григор’єва Д. С. Дослідження параметрів гідроаероіонного складу повітря робочого приміщення з ультразвуковою іонізацію. Вісті Донецького гірничого інституту. 2020.2(47).168−174.