Temperature-humidity regime in the operation of the roofs of historic buildings

Authors

DOI:

https://doi.org/10.26906/znp.2021.57.2584

Keywords:

attic floor, insulation, temperature and humidity conditions

Abstract

The article presents the experience of developing engineering solutions for the restoration and preservation of cold pitched attic structures on the example of a historic building in Poltava. A preliminary design solution for the thermal modernization of the attic floor was analyzed, which included the placement of mineral wool insulation in the attic in accordance with requirements of DBN V.2.6-31:2016 with a thickness of 250 mm. Increasing the thickness of the insulation to modern requirements for energy efficiency on a reinforced concrete floor could lead to a decrease in the temperature in the attic, which, in turn, would not contribute to the melting of snow on the roof, which occurred in the last 70 years of the building's operation. A possible increase in snow load along with cooling of the steel truss elements to -20°C can cause brittle fracture of truss elements made of boiling steel. The thickness of the insulation along the attic floor should be taken no more than 100 mm in order to reduce transmission heat losses and maintain a positive temperature in the attic space.

References

Gonçalves L.M.S., Rodrigues H., & Gaspar F. (2017). Nondestructive Techniques for the Assessment and Preservation of Historic Structures. CRC Press.

https://doi.org/10.1201/9781315168685

Morales-Conde M., Rodríguez-Liñán C., Rubio de Hita P. (2013). Application of Non-Destructive Techniques in the Inspection of the Wooden Roof of Historic Buildings: A Case Study. Advanced Materials Research, 778, 233-242

https://doi.org/10.4028/www.scientific.net/amr.778.233

Spišáková M., Mokrenko D. (2021). Renovation of roof structure of historical building – case study. Czech Journal of Civil Engineering, 6(2), 71-81

https://doi.org/10.51704/cjce.2020.vol6.iss2.pp71-81

Källbom A., Almevik G. (2022). Maintenance of Painted Steel-sheet Roofs on Historical Buildings in Sweden, International Journal of Architectural Heritage, 16:4, 538-552

https://doi.org/10.1080/15583058.2020.1808910

Historical Buildings and Energy (2017) edited by G. Franco and A. Magrini, Cham: Springer

https://doi.org/10.1007/978-3-319-52615-7

Kysela P., Ponechal R., Krušinský P., Korenková R. (2021). Pilot monitoring of the internal temperature and humidity in the historic building attic space. Transportation Research Procedia, 55, 1214-1220

https://doi.org/10.1016/j.trpro.2021.07.102

Semko O.V., Yurin O.I., Filonenko O.I., Mahas N.M. (2020). Investigation of the Temperature–Humidity State of a Tent-Covered Attic. Proceedings of the 2nd International Conference on Building Innovations. Lecture Notes in Civil Engineering, 73

https://doi.org/10.1007/978-3-030-42939-3_26

Korenkova R., Krusinsky P., Pisca P. (2013). Analysis of the Impact of Microclimate in a Roof Space on a Gothic Truss Construction, Communications - Scientific Letters of the University of Zilina, 15(4), 27-31

http://dx.doi.org/10.26552/com.C.2013.4.27-31

Avramenko Yu.A., Leshchenko M.V., Mahas N.M., Malyushitsky O.V., Semko V.A., Sklyarenko S.A.,

Filonenko A.I., Yurin A.I., Semko A.V. (2017).

Thermal insulation, repair and reconstruction of flat roofs of civil buildings: allowance. Poltava: Astra

http://dx.doi.org/10.13140/RG.2.2.13440.56328

Filonenko O., Maliushytskyi O., Mahas N. (2018). Design features of thermomodernization of combined roofs. International Journal of Engineering and Technology, 7(3), 111-115

http://dx.doi.org/10.14419/ijet.v7i3.2.14385

DSTU-N B V.2.6-192:2013 Guidelines for the computational assessment of the thermal and moisture state of enclosing structures. (2014). Kiev: Ministry of Regional Development of Ukraine

DBN V.2.6-31:2016. Thermal insulation of buildings. (2016). Kyiv: Ministry of Regional Development of Ukraine

Downloads

Published

2022-09-16

How to Cite

Semko, O., Filonenko, O., Hasenko, L., Mahas, N., & Rudenko, V. (2022). Temperature-humidity regime in the operation of the roofs of historic buildings. Збірник наукових праць Галузеве машинобудування будівництво Academic Journal Industrial Machine Building Civil Engineering, 2(57), 47–52. https://doi.org/10.26906/znp.2021.57.2584