Experimental studies of long-term fatigue of steel sewer structures
DOI:
https://doi.org/10.26906/znp.2020.55.2349Keywords:
underground sewerage structure, steel structure, chemically aggressive environment, crack resistance, deformation, fluidity, tensile strength, viscosityAbstract
The results show that the experimental studies of long-term fatigue (strength) of steel structures of underground sewage structures in a chemically aggressive environment, simultaneously containing chemical ingredients and biologically aggressive bacteria. It is established that long-term fatigue (strength) of steel structures of underground sewage structures is significantly reduced during long-term operation, and especially when exceeding 20 years or more, in chemically aggressive environments of domestic sewage, which often leads to corrosion and mechanical damage. It is shown that in the course of long service life the indicators of long-term fatigue of reinforcing steel rods of reinforced concrete structures are significantly reduced, which causes the formation of cracks in the connection "reinforcement - concrete", which usually leads to the destruction of reinforced concrete pipes and structures as a whole.
References
DBN B.2.6-98:2009 (2009). Constructions of buildings and structures. Concrete and reinforced concrete structures. Basic design provisions. Kyiv: Ministry of Regional Development of Ukraine
Goncharenko D. & Aleinikova A. (2013). Water supply networks of Kharkiv and possible ways to increase their operational durability. MOTROL. Commission of motorization and energetics in agriculture: Polish Academy of sciences, 15(6), 3-10
OFWAT (2004). Maintaining Water and Sewerage Systems in Englandand Wales, OurProposed Approach for the 2004 Periodic Review. London
Alekseev S., Ivanov F., Modry S. & Shissl P. (1990). Durability of reinforced concrete in aggressive environments. Moscow: Stroyizdat
Sanchez-Silva M. & Rosowsky D.V. (2008). Biodeterioration of construction materials: State of the art and future challenges. J. of Materials in Civil Engineering, 20(5), 352-365
Bielecki R. & Schremmer H., (1987). Biogene Schwefelsäure-Korrosion in teilgefüllten Abwasserkanälen. Sonderdruck aus Heft 94 der Mitteilungen des Leichtweiβ-Instituts für Wasserbau der Technischen Universität Braunschweig
Okada T. & Hattori S. (1985). The relationship between the salt concentration in water and the corrosion resistance of structural steel containing 0.37% carbon. Proceedings of the American Society of Mechanical Engineers, 3, 98-107
Medovar L.B., Saenko V.Ya., Us V.I. & Yarosh V.M. (2020). Features of design of bimetallic preparations for production of a reinforcing profile with a corrosion-resistant cladding layer from 316L steel. Industrial construction and engineering structures. Kyiv: SC "Ukrainian Institute of Steel Structures. V.M. Szymanowski », 2-6.
Vynnykov Y.L, Makarenko V.D., Kravets I.A. & Minenko I.S. (2019). Investigation of the reasons for the decrease in the strength of CHP pipelines. Problems of friction and wear. 1 (82), 63 – 68.
http://dx.doi.org/10.18372/0370-2197.1(82).13488
Makarenko V.D., Paliy R.V. & Galichenko E.N. (2004). Physico-mechanical bases of hydrogen sulfide corrosion destruction of field pipelines. Monograph. Chelyabinsk: CNTI
Makarenko V.D., Kovensky I.M. & Prokhorov N.N. (2000). Corrosion resistance of welded metal structures of oil and gas facilities. Moscow: Nedra-Business Center LLC
Makarenko V.D., Maksimov S.Y., Bilyk S.I., Vynnykov Y.L., Kuskov Y.M., Kuzmenko O.G. & Makarenko Y.V. (2021) Corrosion destruction of sewer systems of Ukraine: Monograph. Kyiv: NULES of Ukraine
Bazhenov Yu.M., Demyanova V.S. & Kalashnikov V.I. (2006). Modified high-quality concrete. Moscow: DIA Publishing House
Marinin A.N., Garibov R.B. & Ovchinnikov I.G. (2008). Resistance of reinforced concrete structures to the effects of chloride corrosion and carbonization. Saratov: "RATA"
Sakharov V.N. & Mayorov V.G. (2005). Modern methods of anticorrosive protection of metal structures in hydraulic engineering. Hydraulic construction, 3, 46-50