Strength of fiber concrete (concrete) under local compression according to the theory of plasticity and experimental studies
DOI:
https://doi.org/10.26906/znp.2022.59.3102Keywords:
local compression, strength, variational method, theory of plasticity, fiber concreteAbstract
Local compression of concrete is often implemented in supporting joints of reinforced concrete structures. As a strength calculation method for this case, a variational method in the theory of plasticity is proposed, which is based on the consideration of the failure stage and takes into account the full set of determining factors of strength: the dimensions of the sample, the shape and dimensions of the loading platform, its location, the ratio of the dimensions of the loading device and the element, type and class of concrete (by taking into account both strength characteristics). In experimental studies, the kinematic schemes of failure adopted in the calculation and the influence of determining factors were confirmed. A comparative analysis of the strength calculated by the proposed method with the experimental one for 78 samples showed that they are sufficiently close.
References
Kuznietsova I., Dovzhenko O., Pohribnyi V., Usenko I. (2020). Influence of the sizes and the loading platform form on the strength of concrete elements at local compression. Proceedings of the 2020 Session of the 13th fib International PhD Symposium in Civil Engineering, 2020, 63-69
Kuznietsova I., Dovzhenko O., Pohribnyi V. (2021). Strength of concrete under local compression taking into account the relationship of the element height to the size of the loading area. Ukrainian Journal of Civil Engineering and Architecture, 5(005), 61-67.
doi.org/10.30838/J.Bpsacea.2312.261021.61.802
Chen W.F., Carson J.L. (1974). Bearing capacity of fiber reinforced concrete. ACI Special Publication, SP–44, 209-220
Kameswara Rao C.V.S. (1974). Bearing strength of steel fibre reinforced concrete. Building Science, 9(4), 263-268
Al-Taan S.A. (2005). Bearing capacity of steel fibrous concrete. Al-Rafidain Engineering, 14(1), 1-11
Breitenbücher R. (2014). Experimental and numerical study on the load-bearing behavior of steel fiber reinforced concrete for precast tunnel lining segments under concentrated loads. Proceedings of Joint ACI-fib International Workshop: Fibre Reinforced Concrete: from Design to Structural Applications, 431-443
Keras V., Augonis M., Adamukaitis N., Vaitekūnaitė E. (2015). Research of local compression concrete reinforced by steel fibres. Journal of Sustainable Architecture and Civil Engineering, 2(No. 11, 72-78.
doi.org/10.5755/j01.sace.11.2.12568
Song F. (2017). Steel fiber reinforced concrete under concentrated load. Dissertation for the degree Doctor of Engineering (Dr.-Ing.). Ruhr University, Bochum
Novitsky A.G. (2010). Aspects of the use of basalt fiber for concrete reinforcement. Scientific and technical collection "Construction materials, products and sanitary equipment" Kyiv, Vol. 36, 22-26
Kuznietsova I. (2022). Strength of fiber concrete elements under local compression. Findings of modern engineering research and developments: Scientific monograph. Riga, Latvia: «Baltija Publishing», 214-232
doi.org/10.30525/978-9934-26-207-4-8
Gladyshev B.M. (1987). Mechanical interaction of structural elements and concrete strength. High school
Piradov A.B. (1973). Structural properties of lightweight concrete and reinforced concrete. Stroyizdat
Dovzhenko O. (1993). Strength of concrete and reinforced concrete elements under local application of a compressive load: dissertation of candidate of technical sciences: spec. 05.23.01. Poltava: PSTU
Ince R. (2004). Size effect in bearing strength of concrete cubes. Construction and Building Materials, 18, 603-609
https://doi.org/10.1016/j.conbuildmat.2004.04.002
Au T. (1960). Bearing capacity of concrete blocks. Journal of the America Concrete Institute, 56, 869-880
Cao H. (2017). Experimental investigation on the static and impact behaviors of basalt fiber-reinforced concrete. The Open Civil Engineering Journal, 11(1), 64-71
doi.org/10.2174/1874149501711010014
SNiP 2.03.01–84. (1989). Concrete and reinforced concrete structures. CITP Gosstroy of the USSR
DSTU B 2.6-156:2010 (2011). Concrete and reinforced concrete structures made of heavy concrete. Design rules. Kyiv, Ministry of Regional Construction of Ukraine, State enterprise "Ukrakhbudinform"
NS 3473:1994. (1994). Concrete structures. Design and detailing rules
DIN 4219-2: 1979. Leichtbeton und Stahlleichtbeton mit geschlossenem. Gefuge; Bemessung und Ausfuhrung
ACI 318-02. (2002). Building Code Requirements for Structural Concrete and Commentary (318-02R). American Concrete Institute, Farmington Hills, Mich
NZ 3101.1:2004. (2004). Concrete Structures Standard: (draft)
Kvasha V.G. (1966). Calculation of the strength of reinforced concrete elements under local compression. Issues of modern construction: Bulletin of the Lviv Polytechnic Institute, 11, 5-14
Niyogi S.K. (1975). Concrete beaming strength-support, nix, size effect. Proc. of Amer. Soc. of Civil Eng. Journ. of the Structural Division, 100, 1685-1702