ELECTRICAL PARAMETERS OF SINGLE MAST UNSYMMETRICAL RADIATOR
Keywords:
antenna with the lower, upper-powered, capacitive load, electrodynamic load Electromagnetic wave resistanceAbstract
The influence of the grounding of the mast on the electrical parameters of single mast radiator with upper capacitive load. An analysis of two main developments of single-mast antennas, antennas with a lower power supply and antennas with an upper power supply are analyzed. Electrical diagrams of different types of asymmetric radiators are given. Describe all the loads that are in the systems. Expressions for the distribution of current and voltage in such systems and the input resistance are obtained by using the Pistolcors equations for electrically asymmetric lines. The solution of the system of equations for unknown currents and voltages at the beginning of each line is performed taking into account the corresponding boundary conditions. The presented relationships provide ample opportunities for numerical calculations to determine the degree of influence of the values of the radii of conductors, the distances between them, the values of loads, their types and locations of installation on the main parameters of such radiators.
Downloads
References
Марков Г.Т., Сазонов Д. М. Антенны. - М .: Энергия, 1975.
Белоусов С.П. и др. Антенны для радиосвязи и радиовещания. Часть 2. Средневолновые и длинноволновые антенны. - М .: Связь, i960.
Муравьев Ю.К. Справочник по расчету проволочных антенн. (Пособие по курсовому и дипломному проектированию). - Л .: ВКАС, 1976.
Гавеля Н.П. Часть I. Под ред. Ю.К. Муравьева. – Л.: ВКАС, 1963.